More comprehensive features
Combine with Hemodialysis, Hemoperfusion, ISO UF , Hemoperfusion,
Plasa Exchange all-in-one
Multi-language LCD touch screen with high defintion display interface
Practicability
In-built battery backup to support 30 minutes after power off
Disinfection:Rinse, hot disinfection and chemic disinfection.Circulated and closed disinfection system
Automatically turn off machine once disinfection process completes
Diameter of blood pump can be adjusted to be flexible for adult and child
Be applicable for various concentration ratio formula
Store treatments information in form of curve profile
Full function digital self-test process
With visual and auditive alarm, character message shows alarm item and troubleshooting on screen
Safety
Air bubble monitor: optical and ultrasonic double control, can monitor blood level and accumulate air bubble
With safe and sensitive blood leakage monitor device
Complete water-way and electric way apart design, individual waterway control system to ensure the security
Dialysate temperature with high precision, safety control at 35-39ºC
Protection from intercross infection, fluid supply loop and return loop is completely divided during disinfection to
Avoid polution of whole machine in the case of mis-sucking disinfection liquid
Conductivity control and protection: conductivity A. mix. conductivity, water outlet conductivity, insure patient's security
Adjustable Na+ curve profile, with multiplicate optional auto-adjust program, can realize indiviual dialysis and ensure patient's safety
Technical Specification:
Extracorporeal circulation system | |
Blood pump flow | 20-620ml/min |
Blood pump segment Dia. | 6.4 and 8mm adjustable |
Heparin pump flow scope | 0~10 ml/h |
Syringe | 10m/20m/30ml;20m/30m/50(optional) |
Arterial and pressure monitor | -300-+400mmHg(±10mmHg) |
Venous pressure monitor | -50~+ 300mmHg(±10mmHg) |
Air bubble detector | infrared and ultrasound detection |
Dialysate system | |
Dialysate flow | 300-800ml/min linearly adjustable(+ 10%,-5%) |
Dialysate temperature scope | 35.0-39.0ºC |
Conductivity | 12.3-15.8mS/cm |
Na+ adjustment scope | 136- 145mmol/L |
HCO3-adjustment scope | 28.0-42.0mmol/L |
Bicarb Cartridge | Optional |
Blood leakage detection | |
Method | Photoelectricity detection |
Ultrafiltration controlling system | |
Ultrafiltration ratio | 0~4000ml/h |
Pump volume accuracy | ±1% |
Disinfection and rinse | |
Rinse and heat disinfection (above 90ºC) | |
Chemical disinfection | Peracetic acid |
Heat chemical disinfection | Citric acid |
Other parameter | |
Dimension | Length*width*height:370mm* 340mm*1450mm |
Weight | 90Kg |
Power supply voltage | 100-240V Ac±10% 50-60HZ |
Power | 1.7KW |
Back-up battery | At least 30 minutes working after electricity cut |
Working environment | Temperature:10-30ºC |
Relative humidity no higher than 70% | |
Water supply temperature | Temperature:5-30ºC |
Dialysate formula | Great compatibility be applicable for various concentration ratio formula |
Pressure | 0.12-0.6Mpa |